Main technical parameter
Compliance standard: EN1413 and CJ128-2007
Temperature measurement range: 0~500° C
Pairing accuracy: ± 0.1 ° C
Protective sleeve: stainless steel 316L, Grade 5
Temperature measuring element: PT 1000/PT 100/PT 500
Connecting wire: PVC, OD4.2mm,two wire system
Pressure resistance PN+16BAR (flow rate 2M/S)
Process connection: movable thread (copper) G:M10*1
Single temperature sensor complies with IEC751 standard, with a B-level error of (0.3+0005lt) ° C
Each pair of temperature probes conforms to the pairing error formula: △ (△T)=5mk/k × △T+90mk
(△T represents the temperature difference measured in min, usually 3 ° C. Our company provides pairing for each pair of temperature probes
Error<01 ° C)
Provide resistance values for three temperature points (40 ° C, 70 ° C, 100 ° C)
Insulation resistance: in accordance with standard JB/T8622-1997, section 5.4
The insulation resistance value of platinum thermistor at room temperature should not be less than 100MQ, with a maximum upper limit temperature insulation resistance
Should be no less than 10MΩ
Use stainless steel probe, use internal sensor, use high temperature Electrical tape,
Avoid short circuits and ensure more stable product quality.PVC outsourcing line.
After food grade processing, excellent material selection and high measurement accuracy
Wide temperature measurement range, practical and convenient, and stable operation.
Support customization
Our company can customize various products that meet customer needs
Please consult customer service for details